Evaluation of the intercept oral specimen collection device with HIV assays versus paired serum/plasma specimens

Greta Beelaert, L Van Heddegem, M Van Frankenhuijsen, G Vandewalle, V Compernolle, E Florence, K Fransen

Onderzoeksoutput: Bijdrage aan tijdschriftA1: Web of Science-artikel

Uittreksel

Oral fluid has many advantages over blood-based techniques: it is less invasive, eliminates the occupational risk associated with needle stick accidents and collection can be self-administrated. Each individual test is packaged with a corresponding collection device. This study tested the suitability of the Intercept Oral Specimen Collection Device for different HIV diagnostic tests: three different rapid HIV tests and two adapted ELISAs, which were evaluated and compared with a gold standard on blood. In addition a total IgG quantification was performed to demonstrate the quality of the specimen. HIV antibodies were detected with a sensitivity of 100%, 99.3%, 98.6%, 100% and 95.7% for, DPP, OraQuick, Aware, Genscreen and Vironostika respectively using the Intercept Collection Device. Respective specificities were 100%, 100%, 99.3%, 97.3% and 100%.

TaalEngels
TijdschriftJournal of Virological Methods
Volume234
Pagina's (van-tot)164-168
Aantal pagina's5
ISSN0166-0934
DOI's
StatusGepubliceerd - 2016